HOW A ROOF ASSEMBLY WORKS
01Roof coveringTiles or metal sheeting; check required detailing
02Roof spaceVentilation, services and suitable installation space
03Selected thermal blanketCorrect uncompressed thickness and continuity
04Ceiling liningFinish, junctions and penetrations
04 / UNDERSTAND THE R-VALUE
Performance is
more than thickness.
R-value measures resistance to heat flow: the larger the number, the more a material resists heat moving through it. Yet the final outcome depends on the entire roof assembly and how carefully it is fitted.
In South Africa, SANS 10400-XA:2021 sets requirements that depend on energy zone, occupancy and the type of roof. A commonly quoted R-value of 3.7 is not a universal rule for every location or project. The designer should check the applicable requirement before materials are specified.
A gap in insulation at a hatch, a crushed blanket at an edge or unsafe fitting around a service can compromise the result. Good insulation practice protects continuity without blocking essential ventilation or creating electrical or fire hazards.
Read about ceiling benefits ↗